Term Meaning
Anodic Stripping Voltammetry (ASV) Electrochemical technique used to quantify dissolved arsenic by depositing arsenic onto an electrode followed by electrochemical stripping.
Baseline Background signal used when determining peak height.
Confidence Interval Statistical estimate of uncertainty associated with a calculated concentration.
Counter electrode Electrode that carries current and completes the electrochemical circuit.
Deposition Stage of the measurement during which arsenic accumulates on the working electrode.
Detection Limit Lowest concentration that can be reliably distinguished from background noise.
Electrolyte Conductive solution used for electrochemical measurements.
Groundwater Matrix The complete chemical composition of a groundwater sample.
ICP-MS Inductively Coupled Plasma Mass Spectrometry, a laboratory technique commonly used for trace metal analysis.
Linear range Concentration range where signal increases proportionally with concentration.
LOD Limit of detection; lowest concentration reliably distinguishable from background noise.
OpenArsenic The complete arsenic detection platform consisting of hardware, software, documentation, and analytical procedures.
OpenVoltam Software used for data acquisition, peak analysis, and concentration calculation.
Peak height Difference between the arsenic peak and the baseline. The primary analytical signal used by OpenArsenic.
Reference electrode Electrode that provides a stable reference potential; Ag/AgCl in this method.
Replicate Repeated measurement performed under the same conditions.
Reproducibility Ability of the method to produce similar results when measurements are repeated.
Rodeostat Low-cost open hardware potentiostat used to run electrochemical measurements.
Standard addition Quantification method where known arsenic amounts are added directly to the sample.
Stripping Stage of the measurement during which deposited arsenic is oxidized and released from the electrode surface, producing the analytical signal.
Voltammogram Graph of current versus applied potential generated during an electrochemical measurement.
Working electrode Electrode where arsenic deposition and stripping occur. The current OpenArsenic method uses a gold microwire working electrode.
  • Ag/AgCl Electrode: Silver/silver chloride reference electrode used to provide a stable reference potential.
  • Supporting Electrolyte: Solution added to improve conductivity and stabilize electrochemical measurements.